OmniFIX HS high screen AES/EBU multicore
n x 2 x 0.22 mm² - FRNC
OX22GH..
- 0.22 mm² conductor cross section (AWG 24)
- double shielding (pair and overall Al foil)
- AL/PETP foil bonded to pair jacket for fast assembly
- flame retardant and non corrosive (FRNC)
- CPR class Eca acc. to EN50575
Lieferzeit
2-3 Tage
order code: OX22GH08
fig. shows: | design OX22GH12 |
no. of pairs: | 8 |
outer Ø: | 16.4 mm |
heat of combustion: | 1510 kWh/km |
cable color: | grey |
Stock:
available while stock lasts
€20.86
/ m
incl. German VAT and incl. postage within Germany
this product is available for business customers only
order code: OX22GH12
fig. shows: | design OX22GH12 |
no. of pairs: | 12 |
outer Ø: | 20.4 mm |
heat of combustion: | 2140 kWh/km |
cable color: | grey |
Stock:
available while stock lasts
€30.12
/ m
incl. German VAT and incl. postage within Germany
this product is available for business customers only
order code: OX22GH16
fig. shows: | design OX22GH12 |
no. of pairs: | 16 |
outer Ø: | 22.8 mm |
heat of combustion: | 2740 kWh/km |
cable color: | grey |
Stock:
short-notice delivery possible
€40.32
/ m
incl. German VAT and incl. postage within Germany
this product is available for business customers only
design
cond. construction: stranded tinned copper, 7 x 0.20 mm |
cond. cross section: 0.22 mm² |
insulation: Foam-Skin PE, red & blue |
pair shielding: stranded tinned copper drain wire + AL/PET foil |
pair jacket: LSZH (low smoke zero halogen) numbered, grey |
overall shield: AL/PET foil + tinned stranded drain wire + tinned copper braid (coverage 85%) |
outer jacket: FRNC |
mechanics
min. bending radius: 10x overall diameter |
working temperature: -30°C / +70°C |
flame retardancy: acc. to IEC 60332-1-2 and IEC60332-3-24 |
halogen-free: acc. to IEC 60754-2 |
electric
conductor resistance: < 85 Ω/km |
capacitance: |
characteristic impedance: 110 Ω |
nom. attenuation [dB/100m]: |
crosstalk attenuation: |
insulation resistance: > 30 GΩ x km |
test voltage: |
Foil-shielded pairs + a double overall shield (foil + very dense briad) provide maximum shielding. The triple shielding and fulfillment of the flame test on bunched cables according to category C make this Omnifix multicore for installations a sure thing in two ways. Interference free, low-loss signal transfer and safety in case of fire by selected LSZH materials for pair and outer jacket, which emit in case of fire, no toxic and halogen-containing gases and very little smoke. The foil shields and pair jackets are bonded to each other and can be processed very quickly.